High Capacity
Dryers
|
|
|
|
| Standard Features |
- Inlet
temperature gauge
- Refrigeration suction pressure gauge
- Refrigeration discharge pressure gauge
- Status indicator lights
- Compressor ON indicator
- Standard NEMA 12 Enclosure
- Single skid mounted
- Air-Water/Glycol heat exchanger
- Air-Air Pre-cooler/re-heater (Economizer)
- Condenser automatic water regulating valve
- Inlet temperature indicator
- Outlet temperature indicator
- Compressor sequencer (for units with multiple
compressors)
- Pump sequencer (for units with duplex pumps)
- Air inlet pressure gauge
- Air outlet pressure gauge
- Zero-purge drain system
- Pump pressure gauge
- Thermal storage temperature gauge
- Rotation protection module
- High-temperature module
- Pump failure indicator
- No-flow indicator
- Pump starter with overload protection
- Compressor starter with overload protection
- Outlet pressure indicator
|
| |
| Optional
Features |
- Duplex
pumping mounted on skid
- Multiplex compressor
- Air-cooled condenser
- Remote condenser
- Compressor sequencer
- Three-valve by-pass
- Mounted pre and after-filter
- Digital dew point monitor
- NEMA 4, 4x or 7 electrical
|
| |
| CRD Series- Cycling
Thermal Mass Refrigerated Dryers |
| |
| CRD - Specifications |
| |
|
Model
|
Capacity
in CFM
|
Comp. HP
|
AIR In/Out
Conn.
FLG
|
Max.
Working
Pressure
PSIG
|
KW
(Full Load)
|
Run Load
Amps
|
Standard
Voltage
|
Dimensions (inches)
|
Weight
(lbs)
|
|
Length
|
Width
|
Height
|
|
3500-CRD
|
3,500
|
2
x 10
|
6"
|
150
|
15
|
37
|
460-3-60
|
130
|
60
|
70
|
3,900
|
|
4000-CRD
|
4,000
|
2
x 10
|
6"
|
150
|
15
|
45
|
460-3-60
|
130
|
60
|
70
|
4,200
|
|
5000-CRD
|
5,000
|
2
x 13
|
8"
|
150
|
19
|
50
|
460-3-60
|
130
|
60
|
75
|
6,000
|
|
6000-CRD
|
6,000
|
30
|
8"
|
150
|
22
|
50
|
460-3-60
|
130
|
70
|
75
|
7,200
|
|
7000-CRD
|
7,000
|
35
|
8"
|
150
|
26
|
65
|
460-3-60
|
135
|
80
|
77
|
8,600
|
|
8000-CRD
|
8,000
|
40
|
10"
|
150
|
30
|
71
|
460-3-60
|
140
|
82
|
80
|
9,800
|
|
9000-CRD
|
9,000
|
50
|
10"
|
150
|
36
|
80
|
460-3-60
|
145
|
85
|
80
|
12,200
|
|
10000-CRD
|
10,000
|
50
|
10"
|
150
|
38
|
91
|
460-3-60
|
145
|
85
|
80
|
12,500
|
|
12000-CRD
|
12,000
|
60
|
12"
|
150
|
45
|
97
|
460-3-60
|
160
|
90
|
80
|
13,800
|
|
15000-CRD
|
15,000
|
2
x 40
|
12"
|
150
|
60
|
138
|
460-3-60
|
180
|
90
|
85
|
17,000
|
|
20000-CRD
|
20,000
|
2
x 50
|
14"
|
150
|
75
|
175
|
460-3-60
|
200
|
100
|
85
|
21,500
|
|
25000-CRD
|
25,000
|
120
|
16"
|
150
|
93
|
186
|
460-3-60
|
210
|
120
|
87
|
23,000
|
|
30000-CRD
|
30,000
|
150
|
18"
|
150
|
112
|
195
|
460-3-60
|
230
|
125
|
90
|
27,000
|
|
| Capacity
rated at Standard CAGI Inlet conditions - Pressure
= 100 PSIG, Temperature = 100 Deg. F and Ambient
Temperature = 100 Deg. F |
| |
| NRD
Series – Non-Cycling Refrigerated Dryers |
|
| NRD
- Specifications |
| |
|
Model
|
Capacity
in CFM
|
Comp. HP
|
In/Out Conn.
Inches
|
Max.
Working
Pressure
PSIG
|
Full Load
KW
|
Full Load
Amps
|
Standard
Voltage
|
Dimensions (inches)
|
Weight
(lbs)
|
|
Length
|
Width
|
Height
|
|
3500-NRD
|
3,500
|
2 x 10
|
6"FLG
|
150
|
15
|
45
|
460-3-60
|
130
|
60
|
70
|
3,700
|
|
4000-NRD
|
4,000
|
2 x 10
|
6"FLG
|
150
|
15
|
45
|
460-3-60
|
130
|
60
|
70
|
4,000
|
|
5000-NRD
|
5,000
|
2 x 13
|
8"FLG
|
150
|
19
|
65
|
460-3-60
|
130
|
60
|
75
|
4,800
|
|
6000-NRD
|
6,000
|
30
|
8"FLG
|
150
|
22
|
50
|
460-3-60
|
130
|
70
|
75
|
5,200
|
|
7000-NRD
|
7,000
|
35
|
8"FLG
|
150
|
26
|
63
|
460-3-60
|
135
|
80
|
77
|
6,500
|
|
8000-NRD
|
8,000
|
40
|
10"FLG
|
150
|
30
|
71
|
460-3-60
|
140
|
82
|
80
|
7,500
|
|
9000-NRD
|
9,000
|
50
|
10"FLG
|
150
|
38
|
69
|
460-3-60
|
145
|
85
|
80
|
8,600
|
|
10000-NRD
|
10,000
|
50
|
10"FLG
|
150
|
38
|
69
|
460-3-60
|
145
|
85
|
80
|
9,700
|
|
| Capacity
rated at Standard CAGI Inlet conditions - Pressure
= 100 PSIG, Temp. = 100 Deg. F and Ambient Temp.
= 100 Deg. F.
All above models are standard air-cooled. For
water-cooled units, consult factory. Full load
amps at standard voltage. |
|
 |